ISSN: 2157-7064
						Sharma  DK
	
					    												
Shimla, Himachal Pradesh
India						                            
                            
						
 Research Article
												A Simple and Fast Solid-Phase Extraction GC-ECD Method for the Routine
Assessment of Atrazine Residues in Agricultural Produces 						
Author(s): Sharma DK, Anil Kumar and Mahender
Sharma DK, Anil Kumar and Mahender
             
						
												
				 A simple and rapid solid-phase extraction (SPE) supported Gas Chromatographic-Electron Capture Detection (GC-ECD) method has been presented for the routine determination of atrazine in some common agricultural produces. Equivalent to USP G-42 GC stationary phase, DB-35 ms capillary column and ECD detector was selected on the basis of physical and structural characteristics of atrazine. Temperature programming of 20 minutes with 0.8 mL/min optimized gas flow gave maximum number of the theoretical plates (N=104) and high resolution (Rs~2.1 min) with LOD and LOQ values of 0.001 μg/L and 0.1 μg/L respectively. LOQ achieved by the present method is almost below the maximum residue levels recommended by the European legislation. Satisfactory spiked recoveries of the atrazine were obtained from agricultural produces ranging from 82.2 to 97.8% with relative standard deviations below 3.8.. View More»
				  
												DOI:
												 10.4172/2157-7064.1000353