GET THE APP

The Use of a Beveled Porous-Polypropylene Hollow Fiber for Liquid
Journal of Chromatography & Separation Techniques

Journal of Chromatography & Separation Techniques
Open Access

ISSN: 2157-7064

+44 1300 500008

Short Communication - (2015) Volume 6, Issue 7

The Use of a Beveled Porous-Polypropylene Hollow Fiber for Liquid-Liquid Microextraction in Paper Spray- Mass Spectrometry

Jian-Siang Wang, Pei-Hua Lai, Yea-Wenn Liou, Chien-Chung Chen and Cheng-Huang Lin*
*Corresponding Author: Cheng-Huang Lin, Department of Chemistry, National Taiwan Normal University, 88 Sec. 4, Tingchow Road, Taipei, Taiwan, Tel: +886277346170, Fax: +886229324249 Email:

Abstract

The use of a porous, hollow polypropylene fiber for sample microextraction in paper spray-mass spectrometry is described. After the microextraction process, one of the end of the hollow fiber was cut into a bevel-shaped, and then used directly for electrospray ionization. Since analytes can be extracted from a very dilute solution using this liquid-liquid extraction process, the limit of detection can be dramatically improved, compared to an ordinary paperspray mass spectrometry in which a triangular shaped piece of chromatography paper is used. Detailed information and the use the technique in the analysis of a urine sample are reported.

Keywords: Paper spray-mass spectrometry; p-chloroamphetamine; Porosity-polypropylene; Hollow fiber; Liquid-liquid extraction

Introduction

By using a triangular shaped section of chromatography paper, socalled paper spray-mass spectrometry (paper-spray MS) has opened new insights in the field of mass spectrometric analysis. This method is simple, economical and rapid, since its debut in 2010 [1], and as a result, it has now become a quite popular and important method for use in mass spectrometry. The method has recently been applied successfully in many areas of research, including food science [2-5], biofluid sample [6], protein complexes [7], rapid discrimination of bacteria [8], online chemical monitoring of cell cultures [9], and drugs of abuse in whole blood [10], and even in an ambient inorganic analysis [11]. Some novel alternate techniques based on paper-spray MS have also been reported, including a 3D-printed paper spray ionization cartridge/continuous solvent supply [12] and the rapid detection of cocaine residues by paper spray ionization coupled with ion mobility spectrometry [13], etc. Although various types of paper have been evaluated for use in this area [1,14], chromatography paper continues to be the most commonly used material. In our previous study [15], we compared the normal chromatography paper that is used in paper-spray MS with a series of papers (natural fibers and synthetic fibers), and the findings showed that the limit of detection could be measurably improved when either gampi paper or a poly-L-lactic acid (PLLA) nanofiber sheet was used. This is because gampi paper or a PLLA nanofiber sheet is very tough and extremely thin, which permits sample molecules to be instantly transported and evaporated. Since ionization occurs within a very short period, an abundance of ions is formed, leading to a dramatic improvement in the limit of detection. However, all of these methods have limitations, especially they are difficult to combined with any extraction method. In this paper we report on a combination of the paper-spray technique and an efficient microextraction process [16]. A commercial porosity-polypropylene (PP) hollow fiber [17-24] was used for the microextraction, and, after the microextraction was complete then one of the ends of the PP hollow fiber was cut into a beveled shape and then directly used for electrospray ionization. A series of designer drugs, including p-chloroamphetamine were used model analytes, which permitted the data obtained in this study to be compared to previously acquired data collected in our laboratory, using the same mass spectrometer. Details of the procedures for conducting the microextraction and paper-spray mass spectrometric analysis are also reported in detail.

Experimental

Materials

p-Chloroamphetamine, ketamine, 3,4-methylenedioxymethylamphetamine (3,4-MDMA) were generously donated previously by the Military Police Command, Forensic Science Center, Taiwan. Analytical- grade n-dodecane was purchased from Sigma-Aldrich (MO, USA); acetonitrile, methanol, and acetone were purchased from Merck (Darmstadt, Germany). Chromatographypaper and porous polypropylene hollow fibers (I.D., 0.6 mm; wall thickness, 0.2 mm; averaged pore size; 200 nm) were obtained from Advantec (Japan) and Membrana (Model, PPQ3/1; Wuppertal, Germany), respectively.

Apparatus

The mass spectrometer (Finnigan LCQ Classic LC/MS/MS) used in this study was the same instrument that was used in our previous study [15]. The mass signal was recorded under the full scan mode (m/z, 100 ~ 400). An Xcalibur data system was used for data collection, and the data were converted into an ASCII text file. The capillary temperature and spray voltage were set at 200°C and 3.0 kV, respectively. The tube lens offset and capillary voltage were set at -36 V and 36 V, respectively. A scanning electron microscope (SEM; JSM-6510, JEOL Ltd.) was also used for surface observations.

Procedures for microextraction

In Figure 1, the left photo shows the micro extraction setup used in this study; the right photo shows a SEM (scanning electron microscope) image of one of the ends of the porous-polypropylene hollow fiber. As mentioned above, the averaged pore size was about 200 nm. A 15 mL aliquot of an aqueous stock solution, which was placed in a 20 mL sample vial, contained 0.1 μg/ml of p-chloroamphetamine. In order to improve the effect of the liquid-liquid extraction, 3.5 g NaCl was added to the stock solution, and pH value was adjusted to 11.0 by using a NaOH solution (0.1 M). In the beginning, one end of a section of a PP hollow fiber (length, 7 cm; weight, 0.01 g) was connected the needle of a HPLC syringe (left in the photo) and the other end to a medical syringe (right in the photo), respectively, that had been ultrasonically cleaned in acetone for 5 minutes, and air-dried. The PP hollow fiber that was attached to the needles was then immersed in n-dodecane as a solvent. After several seconds, the inner n-dodecane was removed by blowing air through the interior of the fiber that was attached to the medical syringe, and 20 μL of methanol was injected into the lumen of the fiber. The solvent used for the extraction can be changed if necessary, depending on the type of analyte. Meanwhile, some n-dodecane was retained by the porous fiber-wall. The fiberwall, with the absorbed n-dodecane, plays a very important role as a boundary between the stock solution and the organic solvent used for the extraction. Following this, the PP hollow fiber was placed in the stock solution (mentioned above), which was stirred at 700 rpm for 30 minutes. Finally, the PP hollow fiber was removed and air-dried under ambient conditions.

chromatography-separation-techniques-Microextraction-setup

Figure 1: Left photo: Microextraction setup used in this study; Right photo: A SEM image of one of the ends of the porous-polypropylene hollow fiber.

Experimental conditions

Figure 2 shows a photo of the beveled porous PP hollow fiber spray-mass spectrometry setup used in this study. After completion of the microextraction processes, a portion (2 cm in length) of the PP fiber was used in the following experiments. One of the ends of the hollow fiber was cut into a beveled shape at a 25° angle. The shaped fiber was connected to an ESI needle, in which a high voltage and auxiliary solvent can be applied simultaneously. In this case, the applied voltage was +3 kV and the optimized distance from the tip to the MS inlet was ~ 5 mm. In order to continuously rinse the bevel-shaped PP hollow fiber and the elute the extract, methanol (at a rate of 6 μL/min) was used as an auxiliary liquid. The inset photo shows an expanded portion of the MS inlet and the bevel shaped PP hollow fiber. For comparison, a piece of chromatography paper was cut into a triangular shape (tip degree, 15°), 10 mm in length and 3 mm wide. The sample solution was dropped on the triangular spray-paper, and then directly placed on a paper-holder, in which a high voltage power supply and auxiliary solvent also can be simultaneously applied.

chromatography-separation-techniques-beveled-porous

Figure 2: A photo of the beveled porous PP hollow fiber spray-mass spectrometry setup used in this study. The inset photo shows the expanded portion of the MS inlet and the shape of the PP hollow fiber.

Results and Discussion

Frame A and B in Figure 3 show typical mass spectra of the test sample (p-chloroamphetamine; concentration level, 0.1 μg/ml) obtained from the regular triangle chromatography paper-spray and the beveled end hollow fiber-spray mass spectrometry, respectively. As can be seen, a very minor peak is produced with the regular method, i.e., a triangle-shaped chromatography paper is used, although the concentration level is extremely low. The ion intensity is only 5.86 × 104 counts. It is also clear that an extraction procedure is definitely necessary if the limit of detection is to be improved. In contrast to this, when a microextraction was performed using the new method, the ion intensity was dramatically improved to 1.08 × 106. In the other words, a 20-fold improvement was achieved. Furthermore, when the optimized experimental conditions were used, the extract (p-chloroamphetamine) can be eluted and ionized during ~ 1 min. This indicate that the sample molecules in the porous-polypropylene hollow fiber are transported and evaporated nearly instantly, and, as a result, many more sample molecules can be detected within a very short period of time. Instead of the stock solution described above, a real urine sample was also analyzed. A 15 mL aliquot of a urine sample obtained from a human volunteer; the research on humans complied with the code of ethics of the World Medical Association. After dilution to 1/10, the diluted urine sample was placed in a glass tube and then spiked with a mixture of p-chloroamphetamine, ketamine and 3,4-MDMA (concentration of each, 1 μg/ml, respectively), without any other treatments. Following this, the PP hollow fiber was used for microextraction (extraction time, 30 min). Figure 4 shows a typical mass spectrum obtained from the urine sample. As can be seen, the spiked drugs of abuse can be clearly detected. Some unknown peaks are also observed due to the fact that urine is composed of a complex mixture of compounds. The other compounds in the urine sample interfered with the detection when a triangle-shaped chromatography paper was used (data not shown). However, when the microextraction method was used, not only were the effects of such other compounds depressed, but the target molecules were also concentrated. Thus, we can conclude that the combination of microextraction and a beveled end hollow fiber provide a new approach to the analysis of samples that are present at very low concentrations.

chromatography-separation-techniques-Mass-spectra

Figure 3: Mass spectra of the test sample (p-chloroamphetamine; concentration level, 0.1 μg/mL) obtained for the regular triangle chromatography paper-spray procedure and beveled end hollow fiber-spray mass spectrometry, respectively. Frame A, mass spectrum obtained by the regular method, i.e., use of a triangular shaped chromatography paper; Frame B, a microextraction was performed and the data obtained by the beveled end hollow fiber method.

chromatography-separation-techniques-Mass-spectra

Figure 4: Mass spectra of a urine sample, spiked with a mixture of p-chloroamphetamine, ketamine and 3,4-MDMA (concentration level of each, 1.0 μg/mL, respectively). The spiked urine sample was made alkaline by the addition of 1g of potassium carbonate and was then shaken for 1 min. Following this, the PP hollow fiber was used for microextraction (extraction period, 30 min). A mass spectrum was obtained for the microextraction process followed by the beveled end hollow fiber method.

Conclusion

The development of a novel method for paper-spray mass spectrometry by combining the microextraction method is described, for the first time. When a commercial porous-polypropylene hollow fiber was used for the extraction, the beveled end of the hollow fiber a play the role in ESI similar to that of the typically used triangular shaped chromatography paper. As a result, the limit of detection can be dramatically improved. In addition to a PP hollow fiber, many other types of hollow fibers can be used, as indicated by the results reported in this study. This method is simple and economical, and is suitable for use in the rapid screening of drugs, since it has a high degree of sensitivity, the operating procedure is simple and an ion signal can be observed immediately. We believe this method has the potential for use in practical analyses and can also be regarded as a helpful tool for use, not only in forensic and clinical analysis, but also biomolecules. Further applications are currently being explored.

References

  1. Liu J, Wang H, Manicke NE, Lin JM, Cooks RG, et al. (2010) Development, characterization, and application of paper spray ionization. Anal Chem 82: 2463-2471.
  2. Garrett R, Rezende CM, Ifa DR (2013) Coffee origin discrimination by paper spray mass spectrometry and direct coffee spray analysis. Anal Methods 5: 5944-5948.
  3. Naccarato A, Moretti S, Sindona G, Tagarelli A (2013) Identification and assay of underivatized urinary acylcarnitines by paper spray tandem mass spectrometry. Anal BioanalChem 405: 8267-8276.
  4. Li A, Wei P, Hsu HC, Cooks RG (2013) Direct analysis of 4-methylimidazole in foods using paper spray mass spectrometry. Analyst 138: 4624-4630.
  5. Mazzotti F, Donna LD, Taverna D, Nardi M, Aiello D, et al. (2013) Evaluation of dialdehydic anti-inflammatory active principles in extra-virgin olive oil by reactive paper spray mass spectrometry. Int J Mass Spectrom 352: 87-91.
  6. Wang H, Ren Y, McLuckey MN, Manicke NE, Park J, et al. (2013) Direct quantitative analysis of nicotine alkaloids from biofluid samples using paper spray mass spectrometry. Anal Chem 85: 11540-11544.
  7. Zhang Y, Ju Y, Huang C, Wysocki VH (2014) Paper spray ionization of noncovalent protein complexes. Anal Chem 86: 1342-1346.
  8. Hamid AM, Jarmusch AK, Pirro V, Pincus DH, Clay BG, et al. (2014) Rapid discrimination of bacteria by paper spray mass spectrometry. Anal Chem 86: 7500-7507.
  9. Liu W, Wang N, Lin X, Ma Y, Lin JM (2014) Interfacing microsampling droplets and mass spectrometry by paper spray ionization for online chemical monitoring of cell culture. Anal Chem 86: 7128-7134.
  10. Espy RD, Teunissen SF, Manicke NE, Ren Y, Ouyang Z, et al. (2014) Paper spray and extraction spray mass spectrometry for the direct and simultaneous quantification of eight drugs of abuse in whole blood. Anal Chem 86: 7712-7718.
  11. Cody RB, Dane AJ (2014) Paper spray ionization for ambient inorganic analysis. Rapid Commun Mass Spectrom 28: 893-898.
  12. Salentijn GI, Permentier HP, Verpoorte E (2014) 3D-printed paper spray ionization cartridge with fast wetting and continuous solvent supply features. Anal Chem 86: 11657-11665.
  13. Li M, Zhang J, Jiang J, Zhang J, Gao J, et al. (2014) Rapid, in situ detection of cocaine residues based on paper spray ionization coupled with ion mobility spectrometry. Analyst 139: 1687-1691.
  14. Lin CH, Liao WC, Chen HK, Kuo TY (2014) Paper spray-MS for bioanalysis. Bioanalysis 6: 199-208.
  15. Lai PH, Chen PC, Liao YW, Liu JT, Chen CC, et al. (2015) Comparison of gampi paper and nanofibers to chromatography paper used in paper spray-mass spectrometry.Int J Mass Spectrom 375: 14-17.
  16. Yamini Y, Seidi S, Feizbakhsh R, Baheri T, Rezazadeh M(2014) Liquid-phase microextraction based on two immiscible organic solvents followed by gas chromatography with mass spectrometry as an efficient method for the preconcentration and determination of cocaine, ketamine, and lidocaine in human urine samples. J Sep Sci 37: 2364-2317.
  17. Praveen P, Loh KC(2014) Solventless extraction/stripping of phenol using trioctylphosphine oxide impregnated hollow fiber membranes - Experimental &modeling analysis.ChemEng J 255: 641-649.
  18. Panahi HA, Chabouk M, Ejlali M (2014) Hollow-fiber-supported liquid membrane microextraction of amlodipine and atorvastatin. J Sep Sci 37: 2018-2024.
  19. Sehati N, Dalali N, Soltanpour S, Dorraji MSS (2014) Extraction and preconcentration of tylosin from milk samples through functionalized TiO2 nanoparticles reinforced with a hollow fiber membrane as a novel solid/liquid-phase microextraction technique. J Sep Sci 37: 2025-2031.
  20. Agrahari GK, Verma N, Bhattacharya PK (2014) Removal of benzoic acid from water by reactive extraction using hollow fiber membrane contactor: experiment and modelling. Clean-Soil Air Water 42:901-908.
  21. Alexander JV, Neely JW, Grulke EA (2014) Effect of chemical functionalization on the mechanical properties of polypropylene hollow fiber membranes. J PolymSciPt B-PolymPhys52: 1366-1373.
  22. dos Santos MF, Ferri CC, Seulin SC, Leyton V, Pasqualucci CAG, et al. (2014) Determination of antidepressants in whole blood using hollow-fiber liquid-phase microextraction and gas chromatography-mass spectrometry. Forensic Toxicol 32: 214-224.
  23. Bartosz W, Marcin W, Wojciech C (2014) Development of hollow fiber-supported liquid-phase microextraction and HPLC-DAD method for the determination of pyrethroid metabolites in human and rat urine. Biomed Chromatogr 28: 708-716.
  24. Yang Y, Chen J, Shi YP (2015)Recent developments in modifying polypropylene hollow fibers for sample preparation.Trac-Trends Anal. Chem. 64: 109-117.
Citation: Wang JS, Lai PH, Liou YW, Chen CC, Lin CH (2015) The Use of a Beveled Porous-Polypropylene Hollow Fiber for Liquid-Liquid Microextraction in Paper Spray- Mass Spectrometry. J Chromatogr Sep Tech 6:311.

Copyright: © 2015 Wang JS, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Top