Recent Development of Two-Dimensional Gas Chromatography Mass Spectrometry and its Application

Xiao He* and Xuan Zheng*
 
*Correspondence: Xiao He, College of Chemistry and Environmental Engineering, University of Shenzhen, Shenzhen, China, Email: Xuan Zheng, College of Chemistry and Environmental Engineering, University of Shenzhen, Shenzhen, China, Email:

Author info »

Abstract

The past decades have seen the fast development of multi- dimensional separation technologies, which are capable of separating increasingly complex mixtures. One good example is the comprehensive two-dimensional Gas Chromatography (GC × GC) that can achieve orthogonal separation by connecting two capillary columns with different stationary phases in series and obtain the total peak capacity. In this the new development of GC × GC and its application are discussed, including the upgrading of GC × GC and the modulators, the molecular identification of un-resolved complex compounds, and the significant environmental consequences, etc. The remarkable high peak capacity and the versatile features of GC × GC have attracted wide attention in environmental chemistry and the related disciplines and sub disciplines.

Keywords

Comprehensive two-dimensional gas chromatography; Molecular identification; Toxic equivalency factors

Introduction

Over the past decades of rapid development of instrumentation in the analytical chemistry field, the new generation of multidimensional separation technologies, for example comprehensive two-dimensional gas chromatography (GC × GC) has dramatically improved the separation ability of complex mixtures. In one-dimensional GC, mixtures are separated by their different affinity to the stationary phase, retained by the capillary column, and eluted at different times. They are sequentially identified by the Mass Spectrometry (MS) based on the mass spectrum patterns. GC × GC separates analysts by locating two capillary columns with complementary stationary phases in the oven, e.g., non-polar and polar stationary phases. A modulator is installed to cut the effluents from the 1st column into cryo-focused segments and inject them into the 2nd column. In the original design of the modulation, ambient temperature air was the trapper and resistively heated conductive paint was applied [1]. In the next generation, contemporary thermal modulator was invented using liquid CO2 or N2 as the cryogen, which was able to trap low boiling point compounds efficiently [2-4]. However, the high consumption of cryogen largely elevates the operational cost of routine measurement, thereby impeding the popularization of GC × GC. Recently, great efforts have been made to develop cryogen-free thermal modulators, for e.g., vortex cooler and thermoelectric cooler. For example, Luong et al. introduced a compact Thermal Independent Modulator (TiM) with thermoelectric cooling and mica thermic heating device [5]. The new development of modulators provides portability and flexibility and fosters the wide application of GC × GC.

Literature Review

Multiple research areas benefit from the high peak capacity, selectivity, and sensitivity of the established separation technique, e.g., food chemistry, cigarette industry, petroleum industry, and atmospheric chemistry [6-9]. The related disciplines and the number of research articles published in the past five years using GC × GC are shown in Figure 1. However, GC × GC data treatment can be extremely complicated and demanding. New approaches must be carefully constructed to take the most advantage of multi-dimensional chromatographic information.

chromatography-separation-disciplines

Figure 1: The research disciplines and the number of research articles published in the past five years using GC × GC.

Among the tens of thousands of organic species in the bulk organics, Polycyclic Aromatic Hydrocarbons (PAHs) are genotoxicants. Exposures to PAHs and the derivatives through inhalation, ingestion, and dermal contact are associated with an increased risk of cancer [10,11]. Nevertheless, due to the limitations of analytical instruments and the lack of authentic standards, the enormous airborne PAHs and the derivatives are far less identified, not to mention quantified. Priorities are given to 16 PAHs (i.e., naphthalene, acenaphthylene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benzoanthracene, chrysene, benzofluoranthene, benzofluoranthene, benzopyrene, benzoperylene, indenopyrene, and dibenzoanthracene) that were highlighted by US Environmental Protection Agency (EPA) due to high human risks and persistence in the environment, leaving the majority PAHs unresolved.

Discussion

Past studies have established incomplete combustion processes as the main sources of PAHs and the derivatives on global and regional scales. For example, vehicle exhaust was reported to be the largest contributor to PAHs in urban Xiamen [12]. Only reporting the concentration of the speciated PAHs, for e.g., 16 EPA PAHs, underestimates the levels of vehicular emission by a large scale. 141 possible monocyclic aromatic hydrocarbon or PAH formulas were detected in aerosol samples collected from roadside, urban, and suburban sites in Hong Kong using the ultrahigh-resolution mass spectrometry, confirming that the unspeciated PAHs dominate the total mass outside the 16 US EPA priority PAHs [13].

Ultrahigh-Resolution MS (UHRMS) provides remarkable mass resolving power and mass accuracy (usually mass accuracy < 1 ppm), enabling the determination of molecules without the use of authentic standards. One good example of UHRMS is the Fourier-Transform Ion Cyclotron Resonance MS (FTICR-MS). In principle, FTICR-MS relates the cyclotron frequency in a fixed magnetic field with the mass to charge ratio (m/z).

Equation

Where f is the cyclotron frequency; B is the magnetic field strength; q is the ion charge; m is the molecular ion mass. Masses are resolved by the ion cyclotron resonance frequency as it rotates in the magnetic field, and all ions are detected simultaneously, which differs significantly from other MS techniques. MS resolution can be improved either by increasing the magnet strength or the detection duration time. FTICR-MS provides ultrahigh resolution and mass accuracy that are required to reliably assign the molecular formulas. Peaks were assigned mathematically calculated formulas due to the mass defect of the elements. For example, the nominal mass (International Union of Pure and Applied Chemistry (IUPAC) mass) of C, H, O, N, S, and electron are 12 (12), 1 (1.007825), 16 (15.9949146), 14 (14.003074), 32 (31.97207), and 0 (0.00054858), respectively. For a given ion CcHhOoNnSs, the theoretical molecular mass is:

Equation

Depending on the polarity of the ion source UHRMS iterates c, h, o, n, s values so that the deviation between MWtheoretical and detected MW falls within the mass accuracy of the instrument.

It was found that compared with speciated PAHs, the unspeciated PAHs accounted for more than 97% of the total PAH mass emitted by Heavy-Duty Diesel Vehicles (HDDVs) [2]. In their study, chassis dynamometer tests were conducted and the gaseous and particulate emissions from one China IV and two China VI HDDVs were collected using Tenax TA sorbent tubes (C1-AXXX-500, Gerstel, Germany) and quartz filters (QM-A, Whatman, UK) separately. Samples were thermally desorbed by an automated thermal desorption system (TD100-xr, Markes, UK) and analyzed by a GC × GC interfaced with a Time-offlight mass spectrometry (ToF-MS, LECO Pegasus4D, LECO Corporation). To deal with the complex GC × GC data, they established a novel “three-step” approach to speciate and quantify the PAHs by constructing class-screening programs based on their characteristic fragments and mass spectrum patterns [3]. Basically, unknown peaks were recognized as the PAH groups once the mass spectrum patterns matched the predefined criteria.

On one hand, speciated PAHs were found to be comparable with previous studies, confirming the robustness of the new method. On the other hand, benefiting from the powerful separation technology and new approach, the un-speciated PAHs were identified and quantified for the first time and the Emission Factors (EFs) were computed. Substantial higher EFs of un-speciated PAHs than speciated PAHs were observed. The un-speciated/speciated PAH ratios were in the range of 84-806 and 34-61 in the particle and gas phases, respectively. Individual PAHs are unequally toxic and the minimum Toxic Equivalency Factors (TEFs) were introduced to evaluate the overall toxicity level in a conservative way [14].

Eqaution

Where TEFPAH is the Benzo(a)pyrene (BaP) equivalent TEF of total PAHs (μg km−1) PAHi is the EF of PAH i (µg km-1 ); TEFi is the minimum TEF of different PAH categories. As expected, Chen et al. reported two orders of magnitude higher BaP equivalent toxic EFs than previous studies, especially in the particle phase [2]. The BaP equivalent toxic EFs of particulate PAHs for China IV and China VI vehicles were 19.2 ± 21.1 and 2.6 ± 1.3 μ gkm in comparison with 0.06 and 0.02 μ gkm-1 for China IV and China V HDDVs reported by Zheng et al [2].

Conclusion

These results have important implications for emission inventory, PAH toxicity estimation, and pollution reduction policies. Un-speciated PAHs call for carful re-evaluation in future work. We rely on solid and accurate measurement of emission data to inform the public and policy makers the real environmental consequences. The findings also motivate the modelers to re-assess the air-quality and toxicology models by incorporating the newly resolved PAH concentrations or TEF values. The complex mixtures are ubiquitous and originate from multiple sources, and this study opens paths for characterizing complex mixtures with the powerful GC × GC plus ingenious data treatment approaches.

Author Contributions

Xiao He (First Author and Corresponding Author): Writing- Original Draft, Validation, Visualization, Funding Acquisition.

Xuan Zheng (Corresponding Author): Project Management, Validation, Funding Acquisition.

Conflict of Interest

The authors declare no competing financial interest.

References

Author Info

Xiao He* and Xuan Zheng*
 
College of Chemistry and Environmental Engineering, University of Shenzhen, Shenzhen, China
 

Citation: He X, Zheng X (2022) Recent Development of Two-Dimensional Gas Chromatography Mass Spectrometry and its Application. J Chromatogr Sep Tech. 13: 491.

Received: 17-Aug-2022, Manuscript No. JCGST-22-18886; Editor assigned: 22-Aug-2022, Pre QC No. JCGST-22-18886(PQ); Reviewed: 05-Sep-2022, QC No. JCGST-22-18886; Revised: 12-Sep-2022, Manuscript No. JCGST-22-18886 (R); Published: 19-Sep-2022 , DOI: 10.35248/2157-7064.22.13.491

Copyright: © 2022 He X, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Top