GET THE APP

Ocular Aberrations and Corneal Thickness-Intraocular Pressure Rel
Journal of Clinical and Experimental Ophthalmology

Journal of Clinical and Experimental Ophthalmology
Open Access

ISSN: 2155-9570

+44 1223 790975

Research Article - (2015) Volume 6, Issue 5

Ocular Aberrations and Corneal Thickness-Intraocular Pressure Relationship One Year after Laser in situ Keratomileusis (LASIK) Enhancement with An Aspheric Ablation Profile

Maja Bohac1*, Marija Anticic1, Mateja Koncarevic1, Alma Biscevic1, Vesna Cerovic1, Nikica Gabric1 and Sudi Patel1,2
1University Eye Hospital, Svjetlost, Heinzelova 39, Zagreb, Croatia
2NHS National Services Scotland, 1 South Gyle Cres, Edinburgh, UK
*Corresponding Author: Maja Bohac, MD, Heinzelova 39, 10 000 Zagreb, Croatia, Tel: +385 91 2304344, Fax: +385 1 7775600 Email:

Abstract

Objective: To evaluate the effect of an aspheric LASIK refractive enhancement performed by relifting the original flap on the higher order aberrations (HOA) of the eye and the relationship between central corneal thickness (CCT) and intra-ocular pressure (IOP). Methods: Consecutive case series of 30 eyes requiring refractive enhancement from 1804 uncomplicated primary LASIK procedures performed in 2012. Flap relift and wavefront optimized ablation (Wavelight Allegretto Eye Q 400 Hz excimer laser) were performed in all cases. Pre-and post-operative examination included Shack-Hartmann aberrometry for 3 mm and 5 mm pupil sizes, CCT and IOP. Postoperative results at 1 year were compared to baseline values. Results: Changes in average values of coma, spherical aberration (SA), trefoil, CCT and IOP were not significant. Linear regression revealed significant associations between change (y) in trefoil and pre-enhancement value of trefoil for 3 mm pupil (0.828x-0.045, r=0.722, p<0.001), coma and pre-enhancement value of coma for 5 mm pupil (y=0.281x-0.030, r=0.501, n=30, p=0.048), SA for 3 mm pupil compared with change in CT (y=0.0080-0.0009x, r=-0.378, p=0.0392), and SA for 5 mm pupil compared with change in CCT (y=0.0035x-0.0541, r=0.524, p=0.0029). Also there was a significant association between IOP and CCT both pre-(IOP=0.0313CT-3.3, r=0.740, p<0.0001) and post-enhancement (IOP=0.0243CT-0.018, r=0.675, p<0.0001). Conclusion: LASIK enhancement with an aspheric ablation profile did not significantly impact on the average values for HOAs, IOP or CCT. For individual cases, the likely shift in magnitude of coma, trefoil and SA can be estimated and, the change in SA is correlated with changes in CCT. The change in the abscissa value linking IOP with CCT may be an indication of changes in biomechanical properties of the cornea in the central region.

Keywords: Corneal thickness; High order aberrations (Hoas); Intraocular pressure (IOP); LASIK enhancement; Excimer laser; Wavefront; Wavelight allegretto

Introduction

Laser in situ keratomileusis (LASIK) is the most frequently applied corneal refractive surgical procedure today [1]. Patients’ satisfaction has risen as the technology has advanced. The reported rate of refractive enhancement or retreatment has been reducing over the last two decades. Miscorrections ≥ 1.00 D were prevalent in up to 59% of cases in reports over the period 1994-97 [2-8]. More recently, a retrospective study on 37,932 procedures treated between 1998-2007 revealed post-op refraction off target greater than ± 1D in just 7% of cases [9]. Since 2000, the reported rate for retreatment averages at about 4% [10-12], increasing to 20% in myopic patients after 10 years according to one source [13].The original nomograms for excimer laser photoablation were based on relatively simple spherical optics. This led to an increase in the magnitude of other higher order aberrations of the eye, and this was associated with reduced visual performances. Opinions have changed and an accepted view is that, besides the correction of sphero-cylindrical refractive error, there is a need to either maintain or reduce the magnitude of higher order aberrations of the eye such as coma and spherical aberration [14-27]. This culminated in the development of more complex algorithms, such as aspheric and wavefront corrected ablation profiles, as mechanisms to control the ocular higher order aberrations [28-30]. There is evidence suggesting that complex algorithms may not, in themselves, lead to more acceptable clinical outcomes [31]. Do these complex algorithms retain, reduce or increase the HOA of the eye after enhancement procedures? The evidence in the literature is inconclusive regarding enhancement procedures.

Hu et al. [32] claimed that intra-ocular pressure influenced the HOA induced by LASIK. The average intra-ocular pressure (IOP) measured by Goldmann tonometry tends to reduce after either PRK or LASIK [33-36] and, the influence of central corneal thickness (CCT) on the measured IOP by applanation tonometry has long been recognized [37-43]. When this is taken into consideration, the change in measured IOP after LASIK is strongly associated with the change in central corneal thickness. Therefore, it is possible that changes in the HOA after LASIK are mediated not just by the measured IOP but also the measured CCT. Enhancement procedures involving further diminution of central corneal thickness are expected to affect the measured IOP and possibly the numerical indices associated with the CCT-IOP relationship. In an extensive review of corneal biomechanics, Garcia-Porta et al. [44] provided a definition of corneal biomechanics as “a branch of science that studies deformation and equilibrium of corneal tissue under application of any force”. Young’s modulus is the constant for a material linking the force per unit area and the corresponding deformation per unit length. This modulus is a marker for the elastic response of the cornea. If Young’s modulus of the treated cornea should change after an enhancement procedure then, the retreated cornea could become less stiff and easier to deform during applanation tonometry. Changes in Young’s modulus may affect the numerical indices of the CCT-IOP relationship.

The aim of this study was to evaluate the results of refractive enhancement after primary uncomplicated LASIK procedure by lifting the original flap and applying an aspheric excimer laser ablation profile by assessing the ocular wavefront aberrations and the relationship between central corneal thickness and intra-ocular pressure (IOP).

Patients and Methods

Study design

This was a consecutive case-by-case series of patients referred for refractive enhancement due to non-tolerated residual refractive error and uncorrected distance visual acuity (UDVA) after primary LASIK performed during 2012. All patients had a mechanical microkeratome cut flap with 90 μm head and superior hinge position (Moria M2 Single Use, Moria, Anthony, France) at the time of the first surgical intervention. Criteria for LASIK refractive enhancement were, unchanged refraction between two consecutive visits 2 months apart, residual spherical equivalent ≥ ± 0.75D, UDVA worse than 0.9 decimal lines (Snellen equivalent 20/22), and residual corneal stromal bed thickness ≥ 300 μm.

All patients were previously treated in our clinic using Wavelight Allegretto Eye-Q 400 Hz (Alcon, Forth Worth, Texas, USA) excimer laser for correction of myopia and, all refractive enhancement procedures were performed on the same excimer laser.

The study was approved by the Ethical Committee of Specialty Eye Hospital “Svjetlost”. The tenets of the Helsinki agreement were followed throughout. All refractive enhancements were performed by the same surgeon.

Preoperative assessment

All patients underwent a complete preoperative ophthalmologic examination prior to deciding if the patient met the criteria for enhancement. Measurements included UDVA (Snellen chart at 6 m), manifest and cycloplegic refraction, corneal topography (Pentacam HR, Oculus Optikgeräte GmbH, Wetzlar, Germany), whole eye aberrometry (L 80 wave+, Luneau SAS, Prunay-le-Gillon, France) for pupil sizes of 3 mm and 5 mm, anterior optical coherence tomography (Visante OCT anterior segment imaging, Carl Zeiss Meditec, Jena, Germany) for evaluation of flap thickness and thickness of residual corneal bed, tonometry (Auto Non-Contact Tonometer, Reichert Inc., Buffalo, NY, USA). Slit lamp and dilated funduscopic examination were also performed. The higher order aberrations (HOAs) evaluated were coma, spherical aberration and trefoil. The L 80 wave+ is a combined autorefractometer, corneal topographer and whole eye aberrometer. The design is based on the Shack-Hartmann aberrometer. Its’ modus operandi has been extensively described elsewhere [45]. The HOAs were measured after 10 minutes adaptation in a dark room without mydriasis. The value for coma was taken as the RMS of the sum of the squared Z-13 and Z13 coefficients. Similarly, the value for trefoil was the RMS of the sum of the squared Z-33 and Z33 coefficients. The value for spherical aberration was the value for the Z04 coefficient. Each of these Zernike polynomials describing the wavefront were computed using the manufacturer’s software built into the L80 wave+. Central corneal thickness values were read off the captured OCT images. All instruments were checked and calibrated according suppliers’ recommendations before use on subjects.

Surgical procedure

The position, diameter and integrity of the flap, site and size of the hinge were inspected just before patients were transferred to the preparation room. Two drops of topical anesthetic were instilled at two minute intervals over 5 minutes before surgery. The eye was cleaned with 2.5% povidone iodine just before lifting the flap. The edge of the flap was located and locally de-epithelized with Merocel sponge (Alcon, Fort Worth, Texas, USA) at the nasal or temporal edge 90° away from hinge. Flat blunt LASIK spatula (Moria, Antony, France) was slid under the flap gently separating flap from underlying corneal bed. After lifting the flap and folding it by placing it on superior conjunctiva, stromal bed thickness was measured using ultrasound pachymeter (PachPen, Accutome, Malvern, PA, USA).

Stromal bed, especially its edges, was thoroughly cleaned with Merocel sponge in radial fashion to remove any residue of epithelial cells. Irrigation was avoided to make sure stromal hydration remained unchanged. After the cleaning of stromal bed, excimer laser ablation was performed on Allegretto Eye Q 400 Hz excimer laser. Wavefront optimized ablation profile was used with the same nomogram adjustment as that used for primary LASIK. The ablation profile was adapted to correct the patients' cycloplegic refraction. After the ablation one drop of oxybuprocaine 0.4% (Novesin, OmniVision GmbH, Puchheim, Germany) was instilled on top the corneal bed while stromal side of the flap was thoroughly cleaned with Merocel sponge to remove any epithelial cells and to prevent flap striae. The flap was repositioned back to its' original position and the interface was irrigated copiously with balanced salt solution. The flap was smoothed out with a wet Merocel sponge. A silicon bandage contact lens was placed on the eye and left in situ for one week.

Postoperative treatment and assessment

All patients were examined one day, one week, one month, three months and one year after the surgery. Evaluation included measurement of UDVA and CDVA, manifest refraction, whole eye aberrometry for pupil sizes of 3 mm and 5 mm, anterior optical coherence tomography for evaluation of corneal thickness, slit lamp and dilated fundus examination, tonometry and corneal topography.

Postoperatively patients were given a combination of topical antibiotic and steroid drops (Tobradex, Alcon, Forth Worth, Texas, USA) 4 times daily for two weeks, and artificial tears (Blink, Abbott Medical Optics, Santa Ana, CA, USA) 6-8 times daily for at least one month.

Analysis of collected data

Data were analyzed to determine the significance of change in the mean high order aberrations (HOAs), central corneal thickness (CCT), and measured intra-ocular pressure (IOP) in comparison to baseline values (Student t-test, 2-sample assuming unequal variances for data with normal distribution and, where appropriate, Mann Whitney U test for nonparametric analysis). Differences were considered significant when p<0.05.

Data were further analyzed by linear regression to determine the significance of any correlation between the induced change in each high order aberration (HOA) with pre-enhancement HOA value, between CCT and IOP both pre- and post-enhancement, and the change in each HOA with the change in CCT. Correlations were considered significant when p<0.05. If a significant correlation was found between CCT and IOP both before and after enhancement then, the difference between the two correlation coefficients were tested for significance of any apparent difference by first, converting each correlation coefficient to a z score using Fischer’s ‘r to z’ transformation (http://quantpsy.org).

Results

Twenty two patients (31 eyes) required a refractive enhancement procedure out of 1804 primary LASIK procedures performed in 2012 leading to a refractive enhancement rate of 1.72%. These patients consisted of 8 females and 14 males. Mean patient age was 43.71 ± 8.67 years (range 25 to 60 years). One eye (one patient) was lost to follow up at one year. Of the patients that completed the study, 23 eyes required sphero-cylindrical correction, 4 eyes required spherical correction and 3 eyes required a cylindrical correction only. Twenty six eyes were predominately myopic and 4 were hyperopic prior to enhancement. Residual refractive errors on case-by-case basis are presented in table 1.

Case-by-case residual refractive error after LASIK enhancement
Patient Eye Sphere (D) Cylinder (D)
N 1 R 0 -1.00
  L 0.25 0
N 2 R 0 -0.25
  L 0.25 -0.50
N 3 R 1.00 -0.50
N 4 R 0.75 -1.00
N 5 R 0 -0.25
  L 0.37 -1.00
N 6 L -0.12 0
N 7 L 0.75 0
N 8 R -0.25 0
  L -0.75 0
N 9 L -0.75 0
N10 R 0.75 -0.75
N11 R 0 -0.25
N12 R 2.25 -2.25
N13 L 0 -0.25
N14 R -0.25 0
N15 L 0.50 -0.25
N16 R -0.25 -0.25
  L -0.50 -0.25
N17 L 0 -0.5
N18 R 0 -0.25

Table 1: Case-by-case residual refractive error after LASIK enhancement.

The high order aberration results are shown in table 2. There was no significant change in the average RMS values for coma, spherical aberration or trefoil for both pupil sizes of 3 mm and 5 mm. Further analysis of the data revealed a significant correlation between the change (Δ) in each HOA and the pre-enhancement HOA value for trefoil (3 mm pupil, r=0.722, p=0.00007) and coma (5 mm pupil r=0.501, p=0.048). These data are shown in figures 1 and 2.

High order aberrations before and after enhancement
Mean ± Standard Deviation
Variable 3mm pupil       5mm pupil
preoperative postoperative p value preoperative postoperative p value
RMS (μm) 0.553 ± 0.20 0.307 ± 0.19 <0.0001 1.369 ± 0.61 0.642 ± 0.51 <0.001
Coma (μm) 0.055 ± 0.05 0.064 ± 0.06 0.536 0.193 ± 0.23 0.169 ± 0.20 0.673
Trefoil (μm) 0.053 ± 0.04 0.054 ± 0.04 0.948 0.158 ± 0.162 0.137 ± 0.13 0.580
SA (μm) -0.005 ± 0.02 0.003 ± 0.03 0.225 -0.019 ± 0.08 -0.007 ± 0.07 0.561
RMS: Root mean square; SA: Spherical aberration; t: test; 2- sample assuming unequal variances

Table 2: Higher Order Aberrations (HOA) before and after enhancement.

clinical-experimental-ophthalmology-regression-line

Figure 1: Change in trefoil and pre-enhancement value of trefoil for 3mm pupil. The least squares regression line equation is: y= 0.828x-0.045, r=0.722, n=30, p<0.001.

clinical-experimental-ophthalmology-line-equation

Figure 2: Change in coma and pre-enhancement value of coma for 5mm pupil. The least squares regression line equation is: y= 0.281x-0.030, r=0.501, n=30, p=0.048.

Mean intraocular pressure (IOP) and central corneal thickness (CCT) values are shown in Table 3. There was no significant change in average IOP and CCT. Linear regression revealed a significant correlation between individual pairs of IOP and CCT measures (r=0.7396, p<0.0001, n=30 pre-enhancement and r=0.6749, p<0.0001, n=30 post-enhancement). The difference between the two correlation coefficients was not significant (z=0.477, p=0.6331). The IOP and CCT values are shown in Figure 3. Reporting the significant findings encountered on further analysis of these data, a significant correlation was found between the change in CCT (ΔCCT) and change in spherical aberration (ΔSA) at 3 mm pupil (r=-0.378, p=0.0392) and 5 mm pupil (r=0.524, p=0.0029). There were no significant correlations between ΔCCT and changes in either coma or trefoil for both pupil sizes.

Central corneal thickness and measured intra-ocular pressure before and after enhancement
Mean ± Standard Deviation (Range)
Variable Preop. Postop.
Central corneal thickness (μm) 518.67 ± 43.68 (448 to 591) 499.8 ± 50.81 (423 to 586)
Intraocular pressure (mmHg) 12.87 ± 1.85 (10 to 17) 12.17 ± 1.86 (9 to 16)
Flap thickness (μm) 102.74 ± 4.85 (95 to 112)  
Intraoperative pachymetry (μm) 416.63 ± 42.79 (344 to 489)  

Table 3: Central corneal thickness (CT) and measured intra-ocular pressure (IOP) before and after enhancement.

clinical-experimental-ophthalmology-corneal-thickness

Figure 3: The relationship between measured IOP and corneal thickness pre -and post-enhancement. Units of IOP (y axis), mmHg. Units of corneal thickness (x axis) μm. The equation of the pre-enhancement linear regression line is: y=0.0313x-3.35 (r=0.740, n=30, p<0.0001). The equation of the post-enhancement linear regression line is: y=0.0243x-0.018, r=0.675, n=30, p<0.0001.

Discussion

The flap relift and reablation technique for residual refractive error after LASIK has been reported to be both safe and effective [46]. For this reason, we accepted this as a reasonable standard procedure for enhancement cases. One of the possible restrictions of this technique is the limitation of the treatment zone with the primary flap and stromal bed diameter and position on the cornea. Our results did not reveal any significant changes in average RMS high order aberration values. Thus, across all 30 cases, the refractive enhancement appears to have corrected only the sphero-cylindrical residual refractive errors but did not affect the overall average optical profiles of the eyes. This has to be viewed with caution. The average HOA values may not change significantly but, this is not true in each individual case. On a case by case basis, individual changes in trefoil and coma were associated with pre-enhancement values. Figure 2 shows that the algorithm of the enhancement procedure has a tendency to reduce the magnitude of coma when pre-enhancement levels of coma is higher than the average. The opposite occurring when the pre-enhancement coma is relatively low. The same can be said for trefoil as shown in Figure 1. Surprisingly, individual changes in spherical aberration were not associated with the pre-enhancement values. However, for both pupil sizes, the changes in spherical aberration were strongly correlated with changes in corneal thickness. However, there are some paradoxes in the HOA data. Firstly, Figure 4 shows that the change in spherical aberration for the 3mm pupil is inversely associated with the change in corneal thickness and in Figure 5 there is direct association between changes in spherical aberration and corneal thickness for the 5 mm pupil. Secondly, changes in the magnitude of HOAs are expected to be more significant for the larger pupil. This was true for coma but, we found that changes in trefoil were associated with pre-enhancement values for the smaller 3 mm pupil not the 5 mm pupil. These anomalies may not be detected in larger samples of enhancement cases with different demographics. Nevertheless, the data we obtained do suggest that different lasers with different algorithms may be preferred if there is an intention to improve the overall optical performance of the eye by, for example, nullifying the HOA values.

clinical-experimental-ophthalmology-spherical-aberration

Figure 4: Change in spherical aberration for 3mm pupil compared with change in central corneal thickness. The least squares regression line equation is: y=0.0080-0.0009x, r=-0.378, n=30, p=0.0392.

clinical-experimental-ophthalmology-central-corneal

Figure 5: Change in spherical aberration for 5mm pupil compared with change in central corneal thickness. The least squares regression line equation is: y=0.0035x-0.0541, r=0.524, n=30, p=0.0029.

The IOP measured by applanation tonometry is strongly associated with the corneal thickness [37-42]. Hence, surgical procedures that ultimately reduce corneal thickness are expected to cause the measured IOP values to reduce [32-36] and, the opposite occurring in procedures leading to increase in thickness [47]. Chang and Stulting [36] studied the effect of refractive correction and the lamellar flap on the measured IOP. They found 0.12 mmHg decrease in IOP per diopter of refractive change. However, extrapolation of their data to a theoretical correction of zero diopter reveals a predicted decrease in measured IOP of 1.36 mmHg. It was claimed that this predicted fall was related to the lamellar corneal flap which makes no contribution to the load bearing characteristics of the post LASIK cornea [36].

An alternative explanation to account for this extrapolated fall in measured IOP could be an induced weakness, a fall in stiffness and rigidity caused by flap creation. Corneal rigidity can be affected by the procedure used to create the flap. Compared with a femtosecond procedure, predicting the change in rigidity when the flap is created using a mechanical microkeratome is compounded by factors such as the variability in the flap thickness profile where the meniscus of the flap is much thicker in the periphery than in the center (especially with the rotatory microkeratomes as used in this investigation), variable hinge length, shallow angled side cut and decreased flap re-adherence to the underlying stromal bed. [48-50]. Our data on correlation between IOP and CCT shown in Figure 3 revealed no significant change in this correlation resulting from the refractive enhancement procedure. This suggests that the overall corneal biomechanical strength within the central region of the cornea is not further compromised by relifting the flap and correcting the small residual refractive error in the enhancement procedure. However, the abscissa value of the least squares line reduced from 3.35 mmHg to 0.02 mmHg. Thus, by extrapolation, for a theoretical value of zero thickness, the predicted shift in the measured IOP value is a fall of 3.33 mmHg. This may be a more realistic practical marker representing the change in the average stiffness of the treated cornea after an enhancement procedure. We found no change in mean IOP or change in the CCT-IOP gradient but, the change in the abscissa that might result from subtle changes in the average biomechanical properties of the cornea. We have been unable to find any other publication showing measured IOP and CCT in cases that have been treated not once but twice with an excimer laser.

In summary, both the optical performance of the eye and expected change in measured IOP can be reasonably predicted on a case-by-case basis following an enhancement procedure using the Wavelight Allegretto Eye-Q 400 Hz excimer laser.

Acknowledgment

We would like to thank Ratimir Lazic, PhD for his critical revision of the manuscript, Adrijana Dukic MD for help in gathering of patients information and Mario Borovcak for his contribution in informatics.

Sources of Funding

Specialty Eye Hospital “Svjetlost”, Zagreb, Croatia.

Conflict of Interest Statement

Maja Bohac, MD-no conflict of interest; Marija Anticic, MD-no conflict of interest; Mateja Koncarevic, MD-no conflict of interest; Alma Biscevic, MD-no conflict of interest; Vesna Cerovic, MD-no conflict of interest; Nikica Gabric, PhD-no conflict of interest; Sudi Patel, PhD-no conflict of interest.

Parts of this manuscript were presented at: ESCRS Milan, Italy, September 2012, Winter ESCRS, Warsaw, February 2013.

References

  1. Duffey RJ, Leaming D (2005) US trends in refractive surgery: 2003 ISRS/AAO survey. J Refract Surg 21: 87-91.
  2. Pallikaris IG, Siganos DS (1994) Excimer laser in situ keratomileusis and photorefractive keratectomy for correction of high myopia. J Refract Corneal Surg 10: 498-510.
  3. Bas AM, Onnis R (1995) Excimer laser in situ keratomileusis for myopia. J Refract Surg 11: S229-233.
  4. Fiander DC, Tayfour F (1995) Excimer laser in situ keratomileusis in 124 myopic eyes. J Refract Surg 11: S234-238.
  5. Kremer FB, Dufek M (1995) Excimer laser in situ keratomileusis. J Refract Surg 11: S244-247.
  6. Güell JL, Muller A (1996) Laser in situ keratomileusis (LASIK) for myopia from -7 to -18 diopters. J Refract Surg 12: 222-228.
  7. Pérez-Santonja JJ, Bellot J, Claramonte P, Ismail MM, Alió JL (1997) Laser in situ keratomileusis to correct high myopia. J Cataract Refract Surg 23: 372-385.
  8. Salah T, Waring GO 3rd, el Maghraby A, Moadel K, Grimm SB (1996) Excimer laser in situ keratomileusis under a corneal flap for myopia of 2 to 20 diopters. Am J Ophthalmol 121: 143-155.
  9. Yuen LH, Chan WK, Koh J, Mehta JS, Tan DT; SingLasik Research Group (2010) A 10-year prospective audit of LASIK outcomes for myopia in 37,932 eyes at a single institution in Asia. Ophthalmology 117: 1236-1244.
  10. Randleman JB, White AJ Jr, Lynn MJ, Hu MH, Stulting RD (2009) Incidence, outcomes, and risk factors for retreatment after wavefront-optimized ablations with PRK and LASIK. J Refract Surg 25: 273-276.
  11. Netto MV, Wilson SE (2004) Flap lift for LASIK retreatment in eyes with myopia. Ophthalmology 111: 1362-1367.
  12. Patel NP, Clinch TE, Weis JR, Ahn C, Lundergan MK, et al. (2000) Comparison of visual results in initial and re-treatment laser in situ keratomileusis procedures for myopia and astigmatism. Am J Ophthalmol 130: 1-11.
  13. Alió JL, Muftuoglu O, Ortiz D et al (2008) Ten-year follow-up of laser in situ keratomileusis for myopia of up to -10 diopters. Am J Ophthalmol 145: 46-54.
  14. Seiler T, Kaemmerer M, Mierdel P, Krinke HE (2000) Ocular optical aberrations after photorefractive keratectomy for myopia and myopic astigmatism. Arch Ophthalmol 118: 17-21.
  15. Moreno-Barriuso E, Lloves JM, Marcos S, Navarro R, Llorente L, Barbero S (2001) Ocular aberrations before and after myopic corneal refractive surgery: LASIK-induced changes measured with laser ray tracing. Invest Ophthalmol Vis Sci 42:1396-1403.
  16. Marcos S (2001) Aberrations and visual performance following standard laser vision correction. J Refract Surg 17: S596-601.
  17. Yamane N, Miyata K, Samejima T, Hiraoka T, Kiuchi T, et al. (2004) Ocular higher-order aberrations and contrast sensitivity after conventional laser in situ keratomileusis. Invest Ophthalmol Vis Sci 45: 3986-3990.
  18. Chalita MR, Chavala S, Xu M, Krueger RR (2004) Wavefront analysis in post-LASIK eyes and its correlation with visual symptoms, refraction, and topography. Ophthalmology 111: 447-453.
  19. Zhang J, Zhou YH, Wang NL, Li R (2008) Comparison of visual performance between conventional LASIK and wavefront-guided LASIK with iris-registration. Chin Med J (Engl) 121: 137-142.
  20. Villarrubia A, Palacín E, Bains R, Gersol J (2009) Comparison of custom ablation and conventional laser in situ keratomileusis for myopia and myopic astigmatism using the Alcon excimer laser. Cornea 28: 971-975.
  21. Kosaki R, Maeda N, Hayashi H, Fujikado T, Okamoto S (2009) Effect of NIDEK optimized aspheric transition zone ablation profile on higher order aberrations during LASIK for myopia. J Refract Surg 25: 331-338.
  22. Serrao S, Lombardo G, Ducoli P, Lombardo M (2011) Optical performance of the cornea six years following photorefractive keratectomy for myopia. Invest Ophthalmol Vis Sci 52: 846-857.
  23. Kamiya K, Umeda K, Igarashi A, Ando W, Shimizu K (2011) Factors influencing the changes in coma-like aberrations after myopic laser in situ keratomileusis. Curr Eye Res 36: 905-909.
  24. Benito A, Redondo M, Artal P (2011) Temporal evolution of ocular aberrations following laser in situ keratomileusis. Ophthalmic Physiol Opt 31: 421-428.
  25. Ivarsen A, Hjortdal J (2012) Seven-year changes in corneal power and aberrations after PRK or LASIK. Invest Ophthalmol Vis Sci 53: 6011-6016.
  26. Kouassi FX, Blaizeau M, Buestel C et al (2012) Comparison of Lasik with femtosecond laser versus Lasik with mechanical microkeratome: predictability of flap depth, corneal biomechanical effects and optical aberrations. J FrOphtalmol. 35: 2-8.
  27. Zhang J, Zhou YH, Li R, Tian L (2013) Visual performance after conventional LASIK and wavefront-guided LASIK with iris-registration: results at 1 year. Int J Ophthalmol 6: 498-504.
  28. Fares U, Suleman H, Al-Aqaba MA, Otri AM, Said DG, et al. (2011) Efficacy, predictability, and safety of wavefront-guided refractive laser treatment: metaanalysis. J Cataract Refract Surg 37: 1465-1475.
  29. Miraftab M, Seyedian MA, Hashemi H (2011) Wavefront-guided vswavefront-optimized LASIK: a randomized clinical trial comparing contralateral eyes. J Refract Surg 27: 245-250.
  30. El Awady HE, Ghanem AA, Saleh SM (2011) Wavefront-optimized ablation versus topography-guided customized ablation in myopic LASIK: comparative study of higher order aberrations. Ophthalmic Surg Lasers Imaging 42: 314-320.
  31. Padmanabhan P, Basuthkar SS, Joseph R (2010) Ocular aberrations after wavefront optimized LASIK for myopia. Indian J Ophthalmol 58: 307-312.
  32. Hu L, Wang Q, Yu P, Yu Y, Zhang D, He JC, Lu F (2013) The influence of intraocular pressure on wavefront aberrations in patients undergoing laser-assisted in situ keratomileusis. Invest Ophthalmol Vis Sci 54:5527-5534.
  33. Schipper I, Senn P, Thomann U, Suppiger M (1995) Intraocular pressure after excimer laser photorefractive keratectomy for myopia. J Refract Surg 11: 366-370.
  34. Mardelli PG Piebenga LW, Whitacre MM, Siegmund KD (1997) The effect of excimer laser photorefractive keratectomy on intraocular pressure measurements using the Goldmannapplanation tonometer. Ophthalmology 104: 945-949.
  35. Chatterjee A, Shah S, Bessant DA, Naroo SA, Doyle SJ (1997) Reduction in intraocular pressure after excimer laser photorefractive keratectomy. Correlation with pretreatment myopia. Ophthalmology 104: 355-359.
  36. Chang DH, Stulting RD (2005) Change in intraocular pressure measurements after LASIK the effect of the refractive correction and the lamellar flap. Ophthalmology 112: 1009-1016.
  37. Hansen FK (1971) A clinical study of the normal human central corneal thickness. ActaOphthalmol (Copenh) 49: 82-89.
  38. Hansen FK, Ehlers N (1971) Elevated tonometer readings caused by a thick cornea. ActaOphthalmol (Copenh) 49: 775-778.
  39. Ehlers N, Bramsen T, Sperling S (1975) Applanation tonometry and central corneal thickness. ActaOphthalmol (Copenh) 53: 34-43.
  40. Ehlers N, Hansen FK, Aasved H (1975) Biometric correlations of corneal thickness. ActaOphthalmol (Copenh) 53: 652-659.
  41. Whitacre MM, Stein R (1993) Sources of error with use of Goldmann-type tonometers. SurvOphthalmol 38: 1-30.
  42. Argus WA1 (1995) Ocular hypertension and central corneal thickness. Ophthalmology 102: 1810-1812.
  43. Wolfs RC, Klaver CC, Vingerling JR, Grobbee DE, Hofman A, et al. (1997) Distribution of central corneal thickness and its association with intraocular pressure: The Rotterdam Study. Am J Ophthalmol 123: 767-772.
  44. Garcia-Porta N, Fernandes P, Queiros A, Salgado-Borges J, Parfita-Mato M, Gonzalez-Meijome JM (2014) Corneal biomechanical properties in different ocular conditions and new measurement techniques. ISRN Ophthalmology 2014: 724546.
  45. Gordon-Shaag A, Millodot M, Ifrah R, Shneor E (2012) Aberrations and topography in normal, keratoconus-suspect, and keratoconic eyes. Optom Vis Sci 89: 411-418.
  46. Sharma N, Balasubramanya R, Sinha R, Titiyal JS, Vajpayee RB (2006) Retreatment of LASIK. J Refract Surg 22: 396-401.
  47. Patel S, McLaughlin JM (1999) Effects of central corneal thickness on measurement of intra-ocular pressure in keratoconus and post-keratoplasty. Ophthalmic Physiol Opt 19: 236-241.
  48. Xia LK, Yu J, Chai GR, Wang D, Li Y1 (2015) Comparison of the femtosecond laser and mechanical microkeratome for flap cutting in LASIK. Int J Ophthalmol 8: 784-790.
  49. Ahn H, Kim JK, Kim CK, Han GH, Seo KY, et al. (2011) Comparison of laser in situ keratomileusis flaps created by 3 femtosecond lasers and a microkeratome. J Cataract Refract Surg 37: 349-357.
  50. Kymionis GD, Kankariya VP, Plaka AD, Reinstein DZ (2012) Femtosecond laser technology in corneal refractive surgery: a review. J Refract Surg 28: 912-920.
Citation: Bohac M, Anticic M, Koncarevic M, Biscevic A, Cerovic V, et al. (2015) Ocular Aberrations and Corneal Thickness-Intraocular Pressure Relationship One Year after Laser in situ Keratomileusis (LASIK) Enhancement with An Aspheric Ablation Profile. Clin Exp Ophthalmol 6:480.

Copyright: © 2015 Bohac M, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Top