Anesthesia & Clinical Research

Anesthesia & Clinical Research
Open Access

ISSN: 2155-6148

Research Article - (2020)Volume 11, Issue 5

Washin of 8% Sevoflurane between Drager Fabius GS and General Electric Avance: An in Vitro Observational Study

 

Author info »

Abstract

Objectives: To in vitro compare sevoflurane washin at FGF=6 l min-1, 9 l min-1 and 12 l min-1 between the General
Electric Avance® and the Dräger Fabius GS anaesthesia workstations. To know whether it is possible to reach an 8%
sevoflurane concentration at each of the FGF studied.
Methods: In this observational in vitro study, three Avance (General Electric, Helsinki, Finland) and three Fabius GS
(Dräger Medical, Lübeck, Germany) anaesthesia workstations were compared. A test lung was connected to the
anaesthesia workstation and a sampling tube was connected from the Y piece of the breathing system to a Cardiocap
S/5 gas analyser (General Electric, Helsinki, Finland). The gas analyser was connected to a computer and sevoflurane
concentration and timeline were recorded every second. Mechanical ventilation was set to 500 ml tidal volume, 12
breaths per minute and FGF (fresh gas flow) of 6, 9 or 12 l min-1. After checking a reading of 0.0 vol% of
sevoflurane, the vaporizer was opened at 8% and data were recorded for 4 minutes (FGF of 6, 9 and 12 l min-1 for
Avance and 12 l min-1 for Fabius) or 7 minutes (FGF of 6 and 9 l min-1 for Fabius)
Results: 90 test were recorded. Time to full washin was: FGF=6 l min-1: 42.30 ± 2.49 s (Avance) and 223.42 ± 13.74 s
(Fabius), p<0.001. FGF=9 l min-1: 34.86 ± 2.54 s (Avance) and 122.40 ± 5.22 (Fabius), p<0.001. FGF=12 l min-1:
29.67 ± 2.06 s (Avance) and 93.81 ± 5.93 (Fabius), p<0.001. 8% washin was only reached at FGF=6 l min-1 for Avance
and Fabius. After plateau, a decay in sevoflurane concentration was observed at all FGF except for Fabius at FGF=6 l
min-1.
Conclusion: Avance is faster than Fabius at all FGF only at FGF of 6 l min-1 can be reached the 8% sevoflurane
concentration. For high concentration sevoflurane inhalational adult anesthesia induction, it is advisable to use
FGF=6 l min-1 and to purge the circuit for at least 42.30 ± 2.49 s (Avance) or 223.42 ± 13.74 s (Fabius).

Author Info

 

Citation: Soliveres J, Docampo C (2020) Washin of 8% Sevoflurane between Dräger Fabius GS and General Electric Avance: An in Vitro Observational Study 11:952. DOI: 10.35248/2155-6148.20.11.952

Received: 05-May-2020 Accepted: 18-May-2020 Published: 25-May-2020

Copyright: © 2019 Soliveres J, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Top