Research article · 15 Sep 2026
Conference abstractPublished 13 Jul 2017
Quantifying therapeutic peptides in human plasma by mass spectrometry: Our experience applied to pharmacokinetic studies in clinical trial
Center for Genetic Engineering and Biotechnology, Cuba
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Mass Spectrometry (MS) has impressive capabilities in terms of sensitivity, resolving power, mass accuracy and different scanmodes versatility. Either alone or in combination with liquid chromatography it is the analytical tool of choice for synthetic therapeutic peptide characterization. Nevertheless, for peptide quantitation in human plasma or other biological sample, the design of the Internal Standard (IS) and the optimization of the sample processing and LC-MS analysis are also key elements for a successful outcome. In consequence, all strategies involving the peptide quantitation in biological fluids are still a challenge and need to be tailored. We present here our recent experiences in the development and validation of customized bioanalytical methods applied to pharmacokinetic studies included in phase I clinical trials. For the absolute quantitation of these three therapeutic peptides, alternatives to the AQUAÃ?® methodology were used. However, the design of the IS, sample processing and mass spectrometry techniques were optimized case by case for CIGB-500, CIGB-300 and CIGB-814 candidates. IS for CIGB-500 and CIGB-814 were synthetic peptides labeled with stable isotopes (13C and/or 15N) in specific residues within the amino acids sequence, instead of IS for CIGB-300 that was a N-terminus acetylated peptide. Sample processing, mainly based on plasma proteins organic or acid precipitation was adapted according to the peptide recovery. In the particular case of CIGB-300, no liquid chromatography separation was needed before MS analysis by MALDI-TOF MS. For CIGB-500 it was applied LC-MS analysis with simultaneous ion monitoring (SIM) in full scan mode. For CIGB-814 it was used LC-MS analysis in single reaction monitoring mode (SRM). The three bioanalytical methods were fully validated and applied to pharmacokinetic (PK) analysis in a phase I clinical trials. It was possible to obtain PK profiles and main PK parameters for all of the assessed candidates.
Subjects
ChemistryAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Longdom does not store it.
More from this journal
The newest in Journal of Chromatography & Separation Techniques.
Commentary · 7 Jul 2025
Development and validation of a quantification method of urinary free cortisol in 24 hours urine by mass detection.
Commentary · 28 Jun 2025
Advancements and Methodologies of Column Chromatography
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Chromatography & Separation Techniques
- SubjectChemistry
- BylineArticles whose byline prints “Ania Cabrales Rico”
