Research articlePublished 2015

Extra-Corporeal Membrane Oxygenation for Arrested Lung Ablative Radiation Therapy

Authors: Gonzalo Pradas Montilla, Victor M Muñoz-Garzón, Julio Vázquez Rodriguez, Jorge Pereira, Juan José Legarra, Rocío Casais, David Aramburu Núñez, Manuel Caeiro Muñoz

Anesthesia & Clinical Research

Volume 6 · Issue 1 · Pages 1–5

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Objectives: Due to breathing movements, radiotherapy of primary lung cancer requires sophisticated methods to ensure accuracy of the high-precision treatment applied. The aim of this study was to show the use of extracorporeal membrane oxygenation for ablative radiotherapy while the lung is totally arrested. Methods: A portable extracorporeal membrane oxygenation device was employed on three separate days without mechanical ventilation to apply stereotactic hypofractionated radiotherapy in three fractions (18 Gy x 3 54 Gy total) to a 68 year old male with a primary tumor (T1N0M0) in the right upper lobe (of the remaining lung). Linear accelerator quality controls (matched isocenter-lasers), patient immobilization monitoring (stereotactic infrared system) and image controls (in cinema mode to observe movements) were made during treatment, and a computed tomography comparison was carried out between pre and post treatment for image verification. Results: Total extra-corporeal membrane oxygenation time was 270, 283 and 380 minutes for each session respectively. Total administered nominal dose was 54 Gy and it was not necessary to discontinue the treatment since neither lung nor tumor movement was observed during this time. During the second and third treatment days, atelectasis appeared, involving the rear of the lower lobe and it was necessary to increase FiO2 to 0,5. The only post-procedure complication has been a seroma in the groin which was resolved with local wound care. Conclusion: The described technique of veno-arterial extra-corporeal membrane oxygenation allows the safe arrest of the lung, the immobilization of the tumor and provides enough time for highly accurate ablative radiation therapy.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Longdom does not store it.

Try:

Similar by topic

More from this journal

The newest in Anesthesia & Clinical Research.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalAnesthesia & Clinical Research
  • SubjectAnaesthesia & Pain
  • BylineArticles whose byline prints “Gonzalo Pradas Montilla”
  • BylineArticles whose byline prints “Victor M Muñoz-Garzón”
  • BylineArticles whose byline prints “Julio Vázquez Rodriguez”
  • BylineArticles whose byline prints “Jorge Pereira”
  • BylineArticles whose byline prints “Juan José Legarra”
  • BylineArticles whose byline prints “Rocío Casais”
  • BylineArticles whose byline prints “David Aramburu Núñez”
  • BylineArticles whose byline prints “Manuel Caeiro Muñoz”