Research articlePublished 2016

Automated detection of Diabetic Retinopathy in Three European Populations

Authors: Morten B. Hansen, Hongying Lilian Tang, Su Wang, Lutfiah Al Turk, Rita Piermarocchi, Martynas Speckauskas, Hans-Werner Hense, Irene Leung, Tunde Peto

Journal of Clinical and Experimental Ophthalmology

Volume 7 · Issue 4 · Pages 1–8

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Objective: Currently 1/12 of the world’s population has diabetes mellitus (DM), many are or will be screened by having retinal images taken. This current study aims to compare the DAPHNE software’s ability to detect DR in three different European populations compared to human grading carried out at the Moorfields Eye Hospital Reading Centre (MEHRC). Participants: Retinal images were taken from participants of the HAPIEE study (Lithuania, n=1014), the PAMDI study (Italy, n=882) and the MARS study (Germany, n=909). Methods: All anonymized images were graded by human graders at MEHRC for the presence of DR. Independently, and without any knowledge of the human grader’s results, the DAPHNE software analysed the images and divided the participants into DR and no-DR groups. Main outcome measures: The primary outcomes were sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of the DAPHNE software with regards to the identification of DR or no-DR on retinal images as compared to the human grader as reference standard. Results: A total of 2805 participants were enrolled from the three study sites. The sensitivity of the DAPHNE software was above 93% in all three studies specificity was above 80%, the PPV was above 28% and the NPV was not below 98.8% in any of the studies. The DAPHNE software did not miss any vision-threatening DR. The areas under the curve (AUC) for all three studies were above 0.96. DAPHNE reduced manual human workload by 70% but had a total false positive rate of 63%. Conclusions: The DAPHNE software showed to be reliable to detect DR on three different European populations, using three different imaging settings. Further testing is required to see scalability, performance on live DR screening systems and on camera settings different to these studies.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Longdom does not store it.

Try:

More from this journal

The newest in Journal of Clinical and Experimental Ophthalmology.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Clinical and Experimental Ophthalmology
  • SubjectOphthalmology & Optometry
  • BylineArticles whose byline prints “Morten B. Hansen”
  • BylineArticles whose byline prints “Hongying Lilian Tang”
  • BylineArticles whose byline prints “Su Wang”
  • BylineArticles whose byline prints “Lutfiah Al Turk”
  • BylineArticles whose byline prints “Rita Piermarocchi”
  • BylineArticles whose byline prints “Martynas Speckauskas”
  • BylineArticles whose byline prints “Hans-Werner Hense”
  • BylineArticles whose byline prints “Irene Leung”