Opinion · 3 Nov 2026
Research articlePublished 15 Mar 2023
Re-Evaluation of Sperm Chromatin Structure Assay (SCSA)
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
The Sperm Chromatin Structure Assay (SCSA) based on the polychromatic fluorescence of Acridine Orange (AO) is widely employed to observe DNA damages in human sperm nuclei. To re-evaluate the principle of the SCSA, human motile sperm with a negative DNA fragmentation rate of 87% were prepared as the Negative Control (NC) and the Positive Control (PC) was prepared through heat denaturation of the NC. The AO stainability for the controls was compared on the basis of microscopic, electrophoretic, and flow cytometric observations. Human motile sperm were separated by means of Percoll density gradient centrifugation and subsequent swim up. Then, DNA fragmentation was observed by the aid of Single-cell pulse-field gel electrophoresis. We found that the AO molecule emitted red and green fluorescence depending on the excitation wavelength. Both controls were changed colour from green to red as the AO concentration increased and lacked red fluorescence after in-gel digestion with trypsin. The change of colour of the NC from red to green and DNA fragmentation proceeded concurrently during photo-bleaching. The cytograms of NC and PC were similar each other. These facts conflict with the SCSA principle. Green and red fluorescence were emitted due to the intercalation of AO into DNA and adsorption of AO to proteins, respectively, and their merge led to the colour variation. Discoloration from red to green during photo-bleaching was possibly observed because green fluorescence from the intercalated AO was more tolerant to reactive oxygen species than red fluorescence from adsorption of AO to some proteins. Overall, SCSA cannot detect DNA damage in the human sperm nucleus.
Keywords
Subjects
Pathology & Lab MedicineAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Longdom does not store it.
More from this journal
The newest in Journal of Medical Diagnostic Methods.
Perspective · 3 Nov 2025
Scientific evaluation of risk assessment methodologies in clinical decision making and healthcare systems
Short communication · 3 Nov 2025
A modern view of personalized medicine in improving treatment effectiveness and patient outcomes
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Medical Diagnostic Methods
- SubjectPathology & Lab Medicine
- BylineArticles whose byline prints “Satoru Kaneko”
- BylineArticles whose byline prints “Kiyoshi Takamatsu”
