Research articlePublished 24 Apr 2023

Revalidation of the Sperm Chromatin Dispersion Test and the Comet Assay Using Intercomparative Studies Between Purified Human Sperm without and with End-Stage DNA Fragmentation

Authors: Satoru Kaneko, Kiyoshi Takamatsu

Journal of Medical Diagnostic Methods

Volume 12 · Issue 2 · Pages 1–13

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Objectives: To perform intercomparative studies to revalidate the principles and quantitative performance of the Sperm Chromatin Dispersion Test (SCD) and Comet Assay (CA). Methods: Human sperm without and with granular fragments in end-stage fragmentation were purified from normozoospermic semen and used as naturally occurring negative and positive controls (NC and PC, respectively). Both SCD and CA extracted nucleoproteins with 2.0 mol/L NaCl, 1.0 mmol/L DTT. SCD determined that DNA damage as inversely proportional to the area of the violet halo. The CA estimated the level of DNA damage electrophoretically from the number of granular fragments; the so-called comet tail, their electrophoretic features were compared with the Single-Cell Pulsed-Field Gel Electrophoresis (SCPFGE). Results: The violet halo in SCD was determined as consisting of Crystal Violet (CV)-stainable nucleoproteins that adhered to the radiated DNA fibers. SCD could not distinguish between NC and PC. The residual nucleoproteins blocked the migration of DNA in the natural CA; in contrast, SCPFGE with in-gel tryptic digestion discharged the fibrous and granular fragments beyond the elongated DNA fibers. The alkaline CA was run DNA in 0.3 mol/L NaOH. Although DNA was shredded to granular fragments, the residual nucleoproteins retained their binding capacity to DNA and still fixed the newly generated fragments. Conclusion: DNA fragmentation analyses require measuring an early stage of fragmentation in separated motile sperm, a lack of proteolysis diminishes the quantitative performances of neutral and alkaline CA. Overall, the results suggested that SCD and CA were insufficiently sensitive as tools to harvest data for clinical statistics.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Longdom does not store it.

Try:

More from this journal

The newest in Journal of Medical Diagnostic Methods.

All its articles

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Medical Diagnostic Methods
  • SubjectPathology & Lab Medicine
  • BylineArticles whose byline prints “Satoru Kaneko”
  • BylineArticles whose byline prints “Kiyoshi Takamatsu”