Short communication · 4 Aug 2026
Conference abstractPublished 20 Oct 2016
Patient-specific MRI-based active contraction and relaxation right ventricle models with different zeroload diastole and systole geometries for better stress and strain calculations
Southeast University, China; Worcester Polytechnic Institute, USA; Harvard Medical School, USA; China Information Tech. Designing and Consulting Institute Co, Ltd, China; Xiamen University, China
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Background: Accurate assessment of ventricular stress and strain is critical for cardiovascular investigations. From a mechanical point of view, zero-stress ventricular geometry information is required for correct stress/strain calculations. Sarcomere shortening in active contraction leads to change of ventricular zero-stress configurations during the cardiac cycle. A new model using different zero-load geometries (diastole and systole) was introduced to provide more accurate diastolic and systolic stress/strain calculations. Methods & Results: Cardiac magnetic resonance (CMR) data were obtained from 16 patients with repaired tetralogy of fallot (TOF) prior to pulmonary valve replacement (8 male and mean age 34.5 years). CMR-based patient-specific computational right and left ventricular (RV and LV) model using one zero-load geometry (old model) and two zero-load geometries (no-load diastole and systole geometries, new model) were constructed and RV mechanical stress and strain were obtained for analysis. Based on the average values from the 16 patients, peak-systolic stress from the new model was 28% higher than that from the old model. Peak-systolic strain from the new model was 40% higher than that from the old model. The new model also provided end-systole and end-diastole stress and strain values that were not available from the old model. Conclusion: The new 2-geometry model may be able to provide more accurate ventricular stress and strain calculations by using different zero-load geometries for the diastole and systole phases, respectively. The new model can be used in patient’s studies to further examine its impact on risk stratification and planning surgical interventions.
Subjects
CardiologyAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Longdom does not store it.
More from this journal
The newest in Clinical and Experimental Cardiology.
Conference abstract · 15 Jun 2026
Speckle Tracking Echocardiography for Early Identification of Chemotherapy-Induced Cardiotoxicity
Conference abstract · 15 Jun 2026
Coronary CT Angiography as a First-Line Diagnostic Tool for Stable Chest Pain: Clinical Outcomes from a Multicenter Study
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalClinical and Experimental Cardiology
- SubjectCardiology
- BylineArticles whose byline prints “Dalin Tang”
- BylineArticles whose byline prints “Pedro J del Nido”
- BylineArticles whose byline prints “Chun Yang”
- BylineArticles whose byline prints “Heng Zuo”
- BylineArticles whose byline prints “Xueying Huang”
- BylineArticles whose byline prints “Rahul H Rathod”
- BylineArticles whose byline prints “Alexander Tang”
- BylineArticles whose byline prints “Zheyang Wu”
