Research article · 15 Sep 2026
Conference abstractPublished 10 Aug 2015
Rapid Ultra flow liquid chromatography –tandem mass spectrometric method for quantification of Dexmethylphenidate in human plasma using Sold Phase Extraction
Department of Pharmaceutical Science, School of Pharmacy, University of Maryland, Baltimore, Maryland, USA. b Piramal clinical research, Hyderabad, Telangana, India. c Vardhaman College of Engineering, Hyderabad, Telangana, Indi
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
A selective, sensitive and reliable method have been developed for quantification of Dexmethylphenidate in human plasma by using UFLCâÂ?Â?MS/MS method. Venlafaxine was used as an internal standard(IS). The extraction of the Dexmethylphenidate from human plasma was performed using solid phase extraction. Reverse phase- Xterra RP 18 (4.6x150mm,5Ã?¼m) column was employed for chromatographic separation of Dexmethylphenidate and Venlafaxine(IS) for MS/MS detection at 1 ml/min flow with mobile phase combination using 90:10 (v/v) Methanol: 5mM Ammonium Acetate (pH 4.00). Detection was performed at transitions of m/z 234.200âÂ?Â?84.000 for Dexmethylphenidate and m/z 278.100âÂ?Â? 58.100 for Venlafaxine by positive electro-spray ionization (ESI+) in multiple reaction monitoring (MRM) mode using tandem mass spectrometry. Retention times were observed with in 3.2 min for both Dexmethylphenidate and Venlafaxine. The calibration curves were linear over a concentration range of 0.201 ng/mL to 80.434 ng/mL for quantification of Dexmethylphenidate with the correlation coefficients demonstrating good linearity (0.996-0.999). The lower limits of quantification were 0.201 ng/mL for Dexmethylphenidate. The developed method was compared in the terms of validation parameters including specificity,linearity, sensitivity, precision, accuracy and stability. Matrix based samples were stable at room temperature for >8 hrs, processed samples were stable at least for >20 hrs and also stable at six freeze-thaw cycles. No significant effect was observed due to the presence of potentially interfering drugs like Paracetamol, Ibuprofen, Caffeine and Aspirin in the plasma sample and also presence of hemolysed or lipemic in plasma sample. The method is validated in human plasma containing K2EDTA as the anticoagulant. This validated method was successfully applied for quantification of Dexmethylphenidate in human plasma for pharmacokinetic bioequivalence study.
Subjects
ChemistryAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Longdom does not store it.
More from this journal
The newest in Journal of Chromatography & Separation Techniques.
Commentary · 7 Jul 2025
Development and validation of a quantification method of urinary free cortisol in 24 hours urine by mass detection.
Commentary · 28 Jun 2025
Advancements and Methodologies of Column Chromatography
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Chromatography & Separation Techniques
- SubjectChemistry
- BylineArticles whose byline prints “Raghunadha Reddy Seelama”
- BylineArticles whose byline prints “Nageswara Rao Pillib”
- BylineArticles whose byline prints “Ravindra Reedy Sc”
- BylineArticles whose byline prints “Sai Satyanaraya Reddyc”