Helix MC Plus high resolution noble gas mass spectrometer at the Australian National University
The Australian National University, Australia; Thermo Fisher Scientific, Germany
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
The Helix MC Plus noble gas mass spectrometer manufactured by Thermo Fisher Scientific is a 350 mm sector, 120 degree, extended geometry, high resolution, multi-collector mass spectrometer for simultaneous acquisition of noble gas isotopes. The Helix MC Plus installed at the Australian National University (ANU) is unique in that it is equipped with three high resolution collectors with 0.3 mm defining slits on the axial (Ax), the high mass (H2) and the low mass (L2) detectors. In contrast, the H1 and L1 detectors are equipped with low mass resolution 0.6 mm collector slits. High mass resolution (>1,800) and mass resolving power (>9,000) achieved with the high resolution collectors make this mass spectrometer unique in analysing noble gas isotopes. It provides the capability to measure isobaric interference free noble gas isotopes in a multi-collector mode, which significantly improves the accuracy to determine isotopic ratios and greatly increases the efficiency of data acquisition. These features will be summarised in the presentation. The Helix MC Plus mass spectrometer at ANU is equipped with four movable detector modules, allowing the four detector positions (H2, H1, L1 and L2) to be adjusted. In order to measure a full suite of noble gases automatically from He to Xe, it is necessary to implement automation of detector positioning for each of noble gas element. This presentation will provide the details of the development of the detector automation currently carried out at ANU, including development of the motorised cup actuators, controller and the software.
Subjects
ChemistryAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Longdom does not store it.
More from this journal
The newest in Journal of Chromatography & Separation Techniques.
Commentary · 7 Jul 2025
Development and validation of a quantification method of urinary free cortisol in 24 hours urine by mass detection.
Commentary · 28 Jun 2025
Advancements and Methodologies of Column Chromatography
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Chromatography & Separation Techniques
- SubjectChemistry
- BylineArticles whose byline prints “Xiaodong Zhang”
- BylineArticles whose byline prints “Masahiko Honda”
- BylineArticles whose byline prints “Doug Hamilton”