Review article · 10 Jun 2025
Conference abstractPublished 10 Aug 2017
Progress and applications of biometry
Wenzhou Medical University, China
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Accurate obtainment of parameters of the eyeball is crucial in both clinic and research. Main parameters include central corneal thickness, anterior chamber depth, axial length, keratometry, lens thickness, white to white, pupil diameter and so on. For example, central corneal thickness is critical laser in situ keratomileusis and glaucoma diagnosis, intraocular lens calculation. The topography was an essential method to evaluate the cornea shape and cornea disease just like keratoconus. Ultrasound was the main method to acquire most of those parameters for years and it was thought as a golden standard. The first optical biometer, the IOLMaster basing on partial coherence interferometry was introduced in 1999. The optical method had shown excellent repeatability and reproducibility in clinic and the accuracy had been confirmed in many studies. Since 2009, several optical biometers are available including the Lenstar, the Aladdin, the AL-Scan, the OA-1000, the Galilei G and the Pentacam AXL. The Lenstar which is based on optical low-coherence reflectometry is another widely used optical biometer comparable to the IOLMaster. Placido’s disk is a widely used technique to provide topography but it is unable to show the posterior surface of cornea. The Orbscan corneal topography system which is an optical-based, slit scanning instrument is the first one which can measures three-space points on the anterior and posterior corneal surfaces. However, it was gradually replaced by the Pentacam using Scheimpflug principle which showed higher repeatability, reproducibility and agreement with Placido. After that, Sirius which combines Placido and Scheimpflug shows its reliability in some studies. More recently, the OA-2000, the IOLMaster 700, the Argos which mainly based on swept-source optical coherence tomography are introduced for dense cataract.
Subjects
Ophthalmology & OptometryAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Longdom does not store it.
Similar by topic
Short communication · 31 Aug 2021
Cradle to Cradle Systems Analysis for Chemical and Biological Engineers: The Role of Progressive Sampling in Possibility Envelope for Value Added Manufacturing Design and Chemical Process Applications
Research article · 2021
Progress in Biotechnological Applications to Coffee Wilt Disease
Conference abstract · 2020
Progress of telerehabilitation after application of machine learning for patients with injuries of the lower extremities
Conference abstract · 19 Mar 2018
Research progress in additive manufacturing of ceramics and some related applications
More from this journal
The newest in Journal of Clinical and Experimental Ophthalmology.
Research article · 6 Oct 2026
Visual performance of wavefront-shaping extended-depth-of-focus intraocular lenses in Japanese eyes after previous laser in situ keratomileusis
Short communication · 30 Aug 2026
Vision Science in the Modern Era: Integrating Neuroscience, Genetics, and Technology
Commentary · 3 Aug 2026
Emerging Frontiers in Experimental Ophthalmology: Innovations and Translational Challenges
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Clinical and Experimental Ophthalmology
- SubjectOphthalmology & Optometry
- BylineArticles whose byline prints “Jinhai Huang”
