Research articlePublished 2017

Development and Validation of RP-HPLC-DAD Stability Indicating Related Substances Method for the Estimation of Impurities of Norethindrone Tablets and their Degradation Products

Authors: Rashidul Islam, Ejazuddin Mohammad Khan, Khursheed Ahmed, Ziyaurrahman Azeez

Pharmaceutical Analytical Chemistry: Open Access

Volume 3 · Issue 2 · Pages 1–11

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

A novel and efficient stability indicating reverse phase High performance liquid chromatography with diode array detector (RP-HPLC-DAD) related substances analytical method has been developed, optimized and validated for the determination of degradation products and process impurities of Norethindrone in Norethindrone tablets: Noreandrostenedione (Imp-A), Norethindrone enolether (Imp-B), Delta-5(6)Norethindrone (Imp-C), Delta-5(10) Norethindrone (Imp-D). The impurities elution and separation was established by optimized gradient chromatographic parameter using Inertsil ODS-3V (150 mm × 4.6 mm) 5 μ analytical column, water and acetonitrile as mobile phase, with run time 55 minutes, diode array detector (DAD) was set up at 210 nm and 240 nm wavelength for the simultaneous analysis of all impurities. The developed HPLC method was validated as per the International Conference on Harmonization (ICH) guidelines. The validation parameters used are Specificity, linearity, accuracy, precision, intermediate precision, and robustness. Limit of detection (LOD) and limit of quantification (LOQ) were also obtained for all impurities. Norethindrone samples and placebo were subjected to stress conditions of hydrolysis (acid and base), oxidative, and thermal stress degradation. Sample and standard solutions stability was also performed. The proposed validated method was successfully used for the quantitative analysis of impurities and degradation products of Norethindrone tablets. The method was found to be suitable for the stability, release, in process and Quality control analysis. The developed method is stability indicating, specific, selective, simple, precise, cost effective, linear and robust.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Longdom does not store it.

Try:

More from this journal

The newest in Pharmaceutical Analytical Chemistry: Open Access.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalPharmaceutical Analytical Chemistry: Open Access
  • SubjectChemistry
  • SubjectPharmaceutical Sciences
  • BylineArticles whose byline prints “Rashidul Islam”
  • BylineArticles whose byline prints “Ejazuddin Mohammad Khan”
  • BylineArticles whose byline prints “Khursheed Ahmed”
  • BylineArticles whose byline prints “Ziyaurrahman Azeez”